Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Free, publicly-accessible full text available December 1, 2025
-
Wearable devices typically use electromagnetic fields for wireless information exchange. For implanted devices, electromagnetic signals suffer from a high amount of absorption in tissue, and alternative modes of transmission (ultrasound, optical and magneto-electric) cause large transduction losses due to energy conversion. To mitigate this challenge, we report biphasic quasistatic brain communication for wireless neural implants. The approach is based on electro-quasistatic signalling that avoids transduction losses and leads to an end-to-end channel loss of only around 60 dB at a distance of 55 mm. It utilizes dipole-coupling-based signal transfer through the brain tissue via differential excitation in the transmitter (implant) and differential signal pickup at the receiver (external hub). It also employs a series capacitor before the signal electrode to block d.c. current flow through the tissue and maintain ion balance. Since the electrical signal transfer through the brain is electro-quasistatic up to the several tens of megahertz, it provides a scalable (up to 10 Mbps), low-loss and energy-efficient uplink from the implant to an external wearable. The transmit power consumption is only 0.52 μW at 1 Mbps (with 1% duty cycling)—within the range of possible energy harvesting in the downlink from a wearable hub to an implant.more » « less
-
To solve the challenge of powering and communication in a brain implant with low end-end energy loss, we present Bi-Phasic Quasi-static Brain Communication (BP-QBC), achieving < 60dB worst-case channel loss, and ~41X lower power w.r.t. traditional Galvanic body channel communication (G-BCC) at a carrier frequency of 1MHz (~6X lower power than G-BCC at 10MHz) by blocking DC current paths through the brain tissue. An additional 16X improvement in net energy-efficiency (pJ/b) is achieved through compressive sensing (CS), allowing a scalable (6kbps-10Mbps) duty-cycled uplink (UL) from the implant to an external wearable, while reducing the active power consumption to 0.52μW at 10Mbps, i.e. within the range of harvested body-coupled power in the downlink (DL), with externally applied electric currents < 1/5th of ICNIRP safety limits. BP-QBC eliminates the need for sub-cranial interrogators, utilizing quasi-static electrical signals for end-to-end BCC, avoiding transduction losses.more » « less
An official website of the United States government
